상세 보기
초록
Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development
- 제목
- 도시철도 객실 공기질 평가모델 개발
- 제목 (타언어)
- Development of Air Quality Assessment Model for Subway Cabin
- 저자
- 권순박; 조영민; 박덕신; 김세영; 박재형; 조관현; 유건종; 김정수
- 발행일
- 2010-06-10
- 학회명
- 2010 한국철도학회 춘계학술대회