The evacuation simulation study was performed with the boundary condition of a fire simulator, referring to Dae-gu Subway Fire Accident which was a real station fire. The subway station was modelled from B3F station building to B2F waiting room in fire simulation. Also, a fire simulation were performed with CFAST and FLUENT. In CFAST, the total 29 zones were divided into 18 station buildings in B3F and 11 station buildings in B2F. In FLUENT, the simulated space had the same establishment as zone of CFAST. The study focused on possibility for application of fire simulation in underground station by comparing the resulted values from two simulators. For application of fire effect, the fire data were loaded directly to EXODUS in the case of CFAST and performed a passenger evacuation simulation. In the case of FLUENT, Out Data values of a fire simulation were difficult to be compatible with EXODUS. Two resulted values of passenger evacuation simulation by fire simulation were compared with the Dae-gu Subway Fire Accident in reality.
- 제목
- CFAST 와 FLUENT 화재유동해석을 통한 승객피난 시뮬레이션 결과 비교분석
- 제목 (타언어)
- The Comparative Analysis of Passenger Evacuation Results Using CFAST and FLUENT
- 저자
- 장용준; 이창현; 박원희; 정우성
- 발행일
- 2007-11-08
- 학회명
- 2007 한국철도학회 추계학술대회