부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가

  • 박대원; 
  • 최수연; 
  • 최재성; 
  • 길경석; 
  • 이강원

초록

In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 mVmax/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 Vmax.

제목
부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가
저자
박대원; 최수연; 최재성; 길경석; 이강원
발행일
2008-06-12
학회명
2008 한국철도학회 춘계학술대회