상세 보기
초록
In this study, comparative analysis on the back-layer phenomena in the tunnel-fire driven flow is performed using numerical simulation with LES and RANS. FDS(Fire Dynamics Simulator) code is employed to calculate the fire-driven turbulent flow for LES and Smartfire code is used for RANS. Hwang and Wargo's data of scaling tunnel fire experiment are employed to compare with the present numerical simulation. The modeled tunnel is 5.4m(L) × 0.4m(W) × 0.3m(H). Heat Release Rate (HRR) of fire is 3.3kW and ventilation-velocity is 0.33m/s in the main stream. The various grid-distributions are systematically tested with FDS code to analyze the effects of grid size. The LES method with FDS provides an improved back-layer flow behavior in comparison with the RANS () method by Smartfire. The FDS solvers, however, overpredict the velocity in the center region of flow which is caused by the defects in the tunnel-entrance turbulence strength and in the near-wall turbulent flow in FDS code.
키워드
- 제목
- 터널화재유동의 역기류 해석을 위한 LES 및 RANS 결과의 비교 고찰
- 제목 (타언어)
- Comparative Study on The Numerical Simulation for The Back-Layer of The Tunnel Fire-Driven Flow with LES and RANS
- 저자
- 장용준; 김학범; 김진호; 한석윤
- 발행일
- 2009-03
- 저널명
- 대한기계학회논문집 B
- 권
- 33
- 호
- 03
- 페이지
- 156 ~ 163
- 언어
- KOR
- 출판사
- 대한기계학회
- 발행국가
- 대한민국
- 분량
- 8 페이지
- ISSN