상세 보기
초록
This study has performed the experimental study to assess the structural safety of a bolster frame that is applied to the bogie system of Korean tilting train. In order to achieve this goal, firstly, loading conditions imposed on the bolster frame were investigated. Based on the international standard and dynamic analysis, the loading conditions were derived. In this study, the dynamic load cases that consider the carbody tilting effect were established. The structural safety of the bolster frame was evaluated by static test under these static loads and the fatigue strength was assessed using Goodman diagram. From the assessment, the bolster frame has satisfied the structural safety. In addition, fatigue test was carried out up to 10x106cycles under tilting load condition established in this study. The inspection of fatigue crack using NDT method was conducted at 6x106 and 10x106cycle. with discrete crack concept. Vibration response spectra and the spectra of forces transmitted through the isolators were computed with respect to stationary dynamic loads. In addition, fatigue properties of concrete structures were examined for given materials’ properties and given geometries. The results indicated that the proposed isolation system 3 can improve fatigue resistance by extending fatigue life and changing the failure mode from shear to flexure."
- 제목
- EXPERIMENTAL STUDY ON THE STRUCTURAL SAFETY ASSESSMENT OF THE TILTING BOLSTER FRAME
- 제목 (타언어)
- EXPERIMENTAL STUDY ON THE STRUCTURAL SAFETY ASSESSMENT OF THE TILTING BOLSTER FRAME
- 저자
- 김정석; 김남포; 한성호
- 발행일
- 2005-11-09
- 학회명
- International Conference on Advanced Nondestructive Evaluation