초록
The concentration of PM in urban railway tunnels (178.1 ug/m3) appears to be higher than that in the metropolitan area (49 ug/m3) addition, even in the case of NOX, which directly affect lung diseases, the concentration in the tunnel was found to be higher than the atmospheric standard of the Ministry of Environment. In this study, we tried to examine the adsorption efficiency on a lab scale by using Activated Carbon Fiber (ACF), which has a high adsorption speed and a high adsorption capacity. As experimental variables, the depth of ACF, the distance between ACF, the flow rate, and the concentration of fine PM and NOx in the tunnel were given. Through experiments, the concentration before and after the filter are checked, and the removal efficiency is checked to derive optimal conditions.
- 제목
- A Study on the Optimum Removal Efficiency of Fine PM Using Activated Carbon Fiber
- 저자
- 김민경; 장예림; 박덕신
- 발행일
- 2020-11-13
- 학회명
- 2020 한국철도학회 추계학술대회
- 개최지
- 제주도
- 개최국가
- 대한민국
- 학회 개최일
- 2020-11-12 ~ 2020-11-13
- 언어
- KOR