상세 보기
지하역사 제연모드 승객피난 성능평가
- 박원희;
- 장희철;
- 정우성;
- 이한수
초록
Heat/smoke detectors are installed in most subway platforms in Korea to detect fire. Subway platform is divided by smoke-control zones for efficient smoke-control. Once the detectors detect heat or smoke, the smoke-control ventilation system in the platform and concourse is activated according to the smoke-control ventilation mode. Smoke-control mode during fires in Korean subway platforms is that the smoke zones operate by exhausting smoke while other zones in the platform and in the concourse which is the upper floor of the platform operate by supplying air or stopping any ventilation. This study is conducted to evaluate performance of passengers' evacuation for various smoke control modes in the subway station. Distribution of smoke and heat due to fire on the platform is analyzed by using Fire Dynamics Simulator(FDS V 4.06) of NIST. Various smoke-control ventilation modes and locations of fire are considered. Evacuation and movement of passengers within the platform is simulated by building EXODUS V.4.0.
키워드
- 제목
- 지하역사 제연모드 승객피난 성능평가
- 제목 (타언어)
- PERFORMANCE EVALUATION OF PASSENGERS' EVACUATION FOR SMOKE-CONTROL MODES IN A SUBWAY STATION
- 저자
- 박원희; 장희철; 정우성; 이한수
- 발행일
- 2008-10
- 저널명
- 한국전산유체공학회지
- 권
- 13
- 호
- 4
- 페이지
- 8 ~ 12
- 언어
- KOR
- 출판사
- 한국전산유체공학회
- 발행국가
- 대한민국
- 분량
- 5 페이지
- ISSN
- P 1598-6071