상세 보기
초록
The electric quality of train is represented by voltage and current harmonics at PT(Ratio 25,000/15/[V]) which is located between pantograph and primary winding of train transformer. In this paper, voltage and current harmonics were measured on the test EMU(electric multiple unit)train with maximum speed of 180km/h in existing railway lines(chungbuk, Taeback, Honam). As a results of test, it is found that the electric quality of train depends on the mostly operation conditions which is accelerating mode and braking mode on each sections. Voltage THD is above all 3[%] and current harmonics is monitored from lowest Harmonic to highest Harmonic in case of accelerating mode. ut, highest current harmonics is not monitored in case of breaking mode. The results in this paper can help to stabilize the power device and power converter of the test EMU train.
키워드
- 제목
- 일반철도선로에서의 전동차 시험운행에 대한 고조파 측정연구
- 제목 (타언어)
- Harmonics Measurement of the Running Test EMU Train in Conventional Railway Lines
- 저자
- 한성호; 손진근; 김영훈
- 발행일
- 2016-06
- 저널명
- 전기학회 논문지 P권
- 권
- 65
- 호
- 2
- 페이지
- 77 ~ 83
- 언어
- KOR
- 출판사
- 대한전기학회
- 발행국가
- 대한민국
- 분량
- 7 페이지
- ISSN
- P 1229-800x