3상/단상 BTB 전압형 컨버터 기반의 전기철도 급전 시스템의 전압제어 향상을 위한 BESS 적용

BESS Application to Voltage Compensation of AC Railway System based on 3?/1? BTB Voltage Source Converter
Citations

SCOPUS

0

초록

The scott transformer changes three-phase power to two single-phase power. However, this method causesunbalance and fluctuation of voltage by the change of electric railload. Recently, the AC railway system based on 3?/1?back-to-back (BTB) voltage source converter (VSC) has been proposed to solve these problems. Meanwhile, batteryenergy storage system (BESS) is used to compensate voltage instantaneously in power system. In this paper, BESSapplication to the AC railway system based on 3?/1? BTB VSC is suggested to compensate voltage instantaneously. Theapplication effect is shown through simulation using MATLAB/SIMULINK.

키워드

3?/1? back to back (BTB) voltage source converter (VSC); Battery energy storage system (BESS); Voltage compensation; AC railway system
제목
3상/단상 BTB 전압형 컨버터 기반의 전기철도 급전 시스템의 전압제어 향상을 위한 BESS 적용
제목 (타언어)
BESS Application to Voltage Compensation of AC Railway System based on 3?/1? BTB Voltage Source Converter
저자
유형준; 신승권; 정호성; 김학만
DOI
10.5370/KIEE.2014.63.11.1588
발행일
2014-11
저널명
전기학회논문지
권
63
호
11
페이지
1588 ~ 1593