상세 보기
초록
In this paper, Application and Comparative Analysis of Anti-windup Method for Improving the Stability of Voltage Control of Auxiliary Power Supplies in Railway System. Because it is easy to design, and the structure is simple, there is a problem in the widely used PI controller to occur. Various problems occur, such as response time delay and overshoot due to integrator windup caused by the accumulation of errors in the integral controller. To improve this, various anti-windup methods have been studied. Among the representative Anti-windup methods, it was checked whether various problems caused by integrator windup could be solved through the conditional integral Anti-windup method and the tracking Anti-windup method and the error control Anti-windup. After confirming through PSIM simulation before hardware experiment, DC power conversion system was designed and improvements were confirmed.
키워드
- 제목
- 철도차량 보조전원장치의 전압 제어 안정성 증대를 위한 Anti-windup 기법의 적용 및 비교 분석
- 제목 (타언어)
- Application and Comparative Analysis of Anti-windup Method for Improving the Stability of Voltage Control of Auxiliary Power Supplies in Railway System
- 저자
- 최종용; 이수길; 이준희; 이현재; 손진근
- 발행일
- 2021-11
- 저널명
- 전기학회 논문지 P권
- 권
- 70
- 호
- 4
- 페이지
- 233 ~ 239