상세 보기
초록
Recently the deeply underground tunnels have been increased along the subway railroads of urban area compared to the past subway railroads. The Shin-Gum-Ho subway station (the Fifth lines, the depth : 46m) which is the third among the deep subway stations in the Korea was chosen as the model of deeply underground stations, and attempted to do simulation of fire. This station consists of three entrance, the basement first floor (B1), the basement second floor (B2), the basement eighth floor or platform (B8) and escalators and stairs from B2 to B8. The total number of grid was about 9,000,000 to make simulation of fire and smoke from the platform to entrance in this research, and the grid system was divided into 19 blocks to increase the efficiency of this simulation. The FDS (Fire Dynamics Simulation) was chosen to make the simulation of fire, and the model of turbulent flow was LES (Large Eddy Simulation). Each block is processed in a CPU using parallel processing of MPI (Message Passing Interface). The resource of CPU for this simulation is a ten of Intel 3.0 GHz Dual CPU (20 CPU).
- 제목
- 대심도 신금호역사의 화재 유동에 대한 고찰
- 제목 (타언어)
- Investigation for Fire Flow of the Deeply Underground Shin-Gum-Ho Subway Station
- 저자
- 장용준; 박일순; 김진호; 정우성; 김학범; 이창현
- 발행일
- 2010-05-31
- 학회명
- 2010 한국철도학회 춘계학술대회