상세 보기
철도차량의 폐기단계에서 냉매시스템 냉매회수효율 향상 연구
Study on the Improvement of Refrigerant Recovery Efficiency of Air-Conditioning System at the End-of-Life Railcar
- 이재영;
- 김희만;
- 천윤영;
- 김용기
초록
The refrigerant of air-condition system at the end-of-life stage of railcar was not recovered efficiently because of no regulations in Korea. We tested the refrigerant recovery efficiency from the air conditioning system to develop a refrigerant recovery device. During the recovery of refrigerant, the refrigerant recovery velocity was reduced steadily by the frozen problem of air-conditioning system because of no power supply at the end-of-life stage. The purpose of this study was to develop the heating system using high-frequency and hot-air. Finally, the total refrigerant recovery period was decreased comparing with the experimental results without heating system.
- 제목
- 철도차량의 폐기단계에서 냉매시스템 냉매회수효율 향상 연구
- 제목 (타언어)
- Study on the Improvement of Refrigerant Recovery Efficiency of Air-Conditioning System at the End-of-Life Railcar
- 저자
- 이재영; 김희만; 천윤영; 김용기
- 발행일
- 2017-05-18
- 학회명
- 2017 한국철도학회 창립20주년 춘계학술발표대회
- 개최지
- 부산항국제여객터미널컨벤션센터
- 개최국가
- 대한민국
- 학회 개최일
- 2017-05-18 ~ 2017-05-20
- 언어
- KOR