상세 보기
전력변환 드라이브 시스템에서 고장 안정성 확보를 위한 상 절체 방식 적용의 Power Relay 동작 지연 특성
- 원영제;
- 이재건;
- 이현재;
- 김길동;
- 손진근
초록
This paper analyzed the transient duration and maximum overshoot according to the operation delay time by applying the phase transfer method for power relay to secure fault stability in a power conversion drive system. The phase transfer method is a method of short-circuiting the faulty phase with two B-contact Power relays and connecting the neutral point to the DC link capacitor for continuous power supply. For the experiment in this study, hardware was manufactured and the power relay was synchronized to the DSP TMS320F28335. A delay was added between the operations of the B-contact power relay and the A-contact power relay to ensure stable power supply when a faulty phase occurs. The optimal relay operation sequence and operation delay time guide lines were presented. In conclusion, it is better to apply only the minimum delay when applying phase transfer method.
키워드
- 제목
- 전력변환 드라이브 시스템에서 고장 안정성 확보를 위한 상 절체 방식 적용의 Power Relay 동작 지연 특성
- 제목 (타언어)
- Delay Characteristics of Power Relay Operation in the Application of Phase Transfer Method for Failure Stability in Power Conversion Drive Systems
- 저자
- 원영제; 이재건; 이현재; 김길동; 손진근
- 발행일
- 2024-11
- 저널명
- 전기학회논문지
- 권
- 73
- 호
- 11
- 페이지
- 2146 ~ 2151