초록
The winding problems of traction motor are a major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tanδ), capacitance and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor.
키워드
- 제목
- 과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화
- 제목 (타언어)
- Properties of Electrical Performance using Accelerated Test by Transient Surge on Stator Coil of Traction Motor
- 저자
- 박현준; 장동욱; 이길헌; 최종선; 김정수
- 발행일
- 2003-01
- 저널명
- 전기전자재료학회논문지
- 권
- 16
- 호
- 9
- 페이지
- 783 ~ 789
- 언어
- KOR
- 출판사
- 한국전기전자재료학회
- 발행국가
- 대한민국
- 분량
- 7 페이지
- ISSN
- P 1226-7945