열차풍 환경의 드론 조종성능 시험장치 구축

Establishment of Drone Control Test Equipment by Train-induced Wind

초록

Drones used to inspect railway facilities can cause accidents due to reduced control performance when highspeed trains generate train-induced wind. Since train-induced winds occur only near trains when another train passes, there are many risks in conducting drone experiments in this field. Therefore, test equipment that can be used in experiments to control the performance of a drone by simulating train-induced wind was established. The maximum wind speed was 15m/ s, sufficient to generate crosswind and upwind, and the size of the drone's test area was 2.5 × 2.5m. As a result of the experiment, the design maximum wind speed was satisfied, and the flow velocity error was within 2% of the maximum. Through a flow velocity region test, it was confirmed that the cross-sectional flow was maintained most constantly at a distance of 4 m from the vent area, and the cross-sectional flow distribution was stable against both crosswinds and upwinds.

키워드

정기점검모니터링Train-induced windDroneRegular inspectionMonitoring열차풍드론
제목
열차풍 환경의 드론 조종성능 시험장치 구축
제목 (타언어)
Establishment of Drone Control Test Equipment by Train-induced Wind
저자
윤혁진김정석김대현박찬호박춘수
DOI
10.7782/JKSR.2022.25.6.457
발행일
2022-06
저널명
한국철도학회논문집
25
6
페이지
457 ~ 464