철도 방음벽 실내 시험 규격안에 대한 연구: 음향 성능 시험방법을 중심으로

A Study on the Laoratory Test Method for Railway Noise Barriers and Related Devices: Test Method for Determining the Acoustic Performance

초록

The number of railway noise barriers is increasing mainly in urban residential areas as a solution for civil complaints on railway noise. Detailed specifications for performance, test criteria, etc., for existing noise barriers tend to differ, and in South Korea, specific standardsfor performance tests for railway noise barriers have not yet been developed. As intensifying environmental standards are necessitatinghigh-performance noise barriers, and as the importance of noise barrier performance and management is increasing in accordance withnoise barriers’ lifespans, performance test standards for railway noise barriers will need to be thoroughly investigated. In this study, domesticand international performance standards were examined to develop effective indoor test standards for railway noise barriers for the SouthKorean railway system. BS EN 16272 was reviewed to develop indoor test methods for determining acoustic performance of noise barriersin a laboratory. We proposed test methods and criteria for transmission loss and sound absorption rates, and an installation method fornoise barrier specimens

키워드

철도소음; 방음벽; 시험규격; 투과손실; 흡음율; Railway noise; Noise barrier; Test method; Sound transmission loss; Sound absorption coefficient
제목
철도 방음벽 실내 시험 규격안에 대한 연구: 음향 성능 시험방법을 중심으로
제목 (타언어)
A Study on the Laoratory Test Method for Railway Noise Barriers and Related Devices: Test Method for Determining the Acoustic Performance
저자
홍지영; 고효인; 박찬경
발행일
2014-08
저널명
한국건축친환경설비학회 논문집
권
8
호
4
페이지
224 ~ 229