상세 보기
대심도 지하역사에서의 화재현상 연구
- 장용준;
- 김학범;
- 이창현;
- 정우성
초록
When the fire occur in the deeply underground subway station, the difficulties of passenger evacuation are expected because of many stairs to the exit. In this study, SOONGSIL-University station (7 line, 47m depth) is the one of the deepest subway stations of the each line in the Seoul metro. The numerical computational-simulation was performed for the fire driven flow in the subway station. Hot and smoke flow was analyzed from the simulation results. The proper plan of evacuation against fire was considered through the results. The fire driven flow was simulated using FDS code in which LES method was applied. The Heat Release Rate was 10MW and the ultrafast model was applied for the growing model of the fire source. The proper mesh size was determined from the characteristic length of fire size. The parallel computational method was employed to compute the flow and heat eqn's in the meshes, which are about 10,000,000, with 6cpu of the linux clustering machine.
- 제목
- 대심도 지하역사에서의 화재현상 연구
- 저자
- 장용준; 김학범; 이창현; 정우성
- 발행일
- 2008-06-12
- 학회명
- 2008 한국철도학회 춘계학술대회