상세 보기
초록
In this study, fire behavior for subway coach fire in the 1/10 reduced scale model is analyzed using numerical analysis method (FDS). The size of the reduced model coach is 1.9 m long, 0.290 m high and 0.235 m. The simulation is carried out only one-sided four doors of the coach are opened. A fire source is the n-heptane pool fire with a mean heat release rate 2.33 kW. Smoke temperature, heat release rate and mass loss rate for the model are calculated.
- 제목
- 지하철 축소모형 객차화재 수치해석적 연구
- 제목 (타언어)
- SIMULATION STUDIES ON A REDUCED-SCALE SUBWAY COACH FIRE
- 저자
- 김동운; 박원희; 김치훈; 정우성; 이덕희
- 발행일
- 2010-05-14
- 학회명
- 2010 한국전산유체공학회 춘계학술대회