The suspended particulate matter (PM) was measured in subway tunnel of Seoul Line 1 to 9 in order to evaluate the pollution degree and characteristics of the PM in the subway tunnel. Also, to analyze the effect of outdoor aerosol concentration on the PM concentration of subway tunnels, the ambient PM concentration around the subway station was extracted by spatial analysis using PM10 data of Seoul air pollution monitoring network. Finally, in order to understand pollution pattern in the Seoul subway tunnels, cluster analysis was performed based on input data set such as PM levels in tunnel, tunnel depth, length, curvature radius, outdoor ambient air pollution levels and so on. The average concentration of PM10, PM2.5, and PM1 on subway tunnels were 98.0±37.4, 78.4±28.7, and 56.9±19.2 μg/m3, respectively. As a result of the cluster analysis, tunnels from Seoul subway Line-1 to Line-9 were classified into five classes, and the concentrations and physical properties of the tunnels were compared. This study can provide a method to reduce PM concentration in tunnel for each pollution pattern and provide basic information about air quality control in Seoul subway tunnel.

키워드

PM; Subway; Tunnel; Cluster analysis; Pattern recognition
제목
서울시 지하철 터널 내 입자상물질의 농도 특성 및 오염형태 분류
제목 (타언어)
Characteristics of Particulate Matter Concentration and Classification of Contamination Patterns in the Seoul Metropolitan Subway Tunnels
저자
이은선; 이태정; 박민빈; 박덕신; 김동술
DOI
10.5572/KOSAE.2017.33.6.593
발행일
2017-12
저널명
한국대기환경학회지
권
33
호
6
페이지
593 ~ 604