자연풍 및 배기운전조건이 섬식 지하역사 승강장 위의 화재에 미치는 영향

Effects of natural wind and exhaust fan operation on the fire on an island type subway station platform
  • 장희철; 
  • 윤경범; 
  • 김태국; 
  • 박원희

초록

In this study effects of natural wind and ventilation operating type are studied numerically to examine the fire characteristics from a fire on the platform of an underground subway station of island type. Ventilation rooms of Munjune station of Pusan Subway Line 2 are located at both ends of the lobby and ventilation is controled separately for two zones at the same flowrate. Effects of natural wind, stairs, stair walls and columns on the distribution of heat, smoke, visibility and toxic gases are studied. The numerical results show that the natural wind causes a rapid spread of the fire along the tunnel. The numerical result also show that the the dual operation of the two ventilation systems result in better smoke rejection efficiency as compared to the single operation of the ventilation systems near the fire.

키워드

Subway station; 배기 판; 섬식승강장; 자연풍; 지하철 역사; 화재; Exhaust fan; Fire; Natural wind; Island type
제목
자연풍 및 배기운전조건이 섬식 지하역사 승강장 위의 화재에 미치는 영향
제목 (타언어)
Effects of natural wind and exhaust fan operation on the fire on an island type subway station platform
저자
장희철; 윤경범; 김태국; 박원희
발행일
2005-12
저널명
기술과학연구소 논문집
권
35
호
2
페이지
37 ~ 47