상세 보기
후드를 이용한 협소 터널 미기압파 감소 효과에 대한 수치적 연구
- 윤수환;
- 김병천;
- 구요천;
- 이동호;
- 권혁빈;
- ... 고태환
초록
The train entry into a tunnel generates a strong compression wave in the tunnel. The high amplitude of compression wave causes high pressure gradients that are responsible for both the aural discomfort of passengers and the impulsive acoustical wave called the miro-pressure wave. This paper provides a numerical study on effects of hood for micro-pressure wave reduction. An axisymmetric numerical solver, considering the cross-sectional area of Korean Tilting Train eXpress, is used for a transient flow field in the tunnel. Results show that the micro-pressure wave is able to be reduced by a hood. In this results, the maximum reduction of micro-pressure wave is shown at 2L(length), 1.35D(diameter) hood around 56% against the non-hood case.
- 제목
- 후드를 이용한 협소 터널 미기압파 감소 효과에 대한 수치적 연구
- 제목 (타언어)
- Numerical Study of effects on micro-pressure wave reduction by a hood on a narrow tunnel
- 저자
- 윤수환; 김병천; 구요천; 이동호; 권혁빈; 고태환
- 발행일
- 2005-11-10
- 학회명
- 2005 한국철도학회 추계학술대회