FDS 및 FLUENT를 이용한 대구지하역사 화재유동 해석비교

초록

The comparative analysis of fire-driven flow simulation for Dae-Gu subway station was performed using FDS and Fluent. The boundary condition was obtained from analyzed data for Dae-Gu subway fire accident which had been outbreaked in 2003 year. The smoke flow in the second and third basement has been analyzed. The CO and temperature distribution in the train units and station platform have been obtained with FDS and FLUENT and compared with each other. Total simulation time is 600s and the results are compared of each 10sec The analyzed data will be applied to the passenger evacuation simulation for Dae-Gu subway station and used to optimal design method.

제목
FDS 및 FLUENT를 이용한 대구지하역사 화재유동 해석비교
저자
장용준; 이창현; 김학범; 김진호
발행일
2008-11-13
학회명
2008 한국철도학회 추계학술대회