Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the seventy of the stresses The electncal aging by transient surge is very important to traction motor in EMU(electric multiple unt). This paper presents the insulation charactenstics of stator coil by transient surge from inverter There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation charactenstics of stator coil were each analyzed by measurement of leakage current, dielectric loss(tan &), capacitance, polarization indexPI) and partial discharge The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor in EMU.
키워드
- 제목
- 과도서지에 의한 견인전동기 고정자 코일의 상태진단 연구
- 제목 (타언어)
- A Study on the Condition Diagnosis for the Stator Coil of Traction Motor by Transient Surg
- 저자
- 박현준; 장동욱; 김길동; 최종선; 김정수
- 발행일
- 2003-06
- 저널명
- 전력전자학회 논문지
- 권
- 8
- 호
- 3
- 페이지
- 247 ~ 252
- 언어
- KOR
- 출판사
- 전력전자학회
- 발행국가
- 대한민국
- 분량
- 6 페이지
- ISSN
- P 1229-2214