Characteristics of persistent-current mode of HTS coil on superconducting electromagnet

Citations

WEB OF SCIENCE

1

초록

This paper investigates the way in which the levitation gap of an electromagnetic suspension (EMS) system affects the current decay rate of superconducting electromagnet (SC-EM) operated in persistence-current mode (PCM). Using inductance analyzed from the magnetic circuit of an EMS model, the current decay rate caused by the variation in the levitation gap was simulated. In order to experimentally verify the simulation results, we fabricated a small-scale EMS model with SC coil operated in PCM and measured the current decay rates at different levitation gaps. The result showed that the presence of iron core provides a significant benefit in the PCM performance of SC coil, but the benefit decreased as the levitation gap increases. This study revealed that the increased levitation gap of the EMS model with the SC-EM could negatively affect the design of SC-EM operated in PCM. (C) 2011 Elsevier B.V. All rights reserved.

키워드

Maglev; EMS; PCM; Superconducting electromagnet; Levitation; CURRENT SWITCH
제목
Characteristics of persistent-current mode of HTS coil on superconducting electromagnet
저자
Lee, C. Y.; Kim, J.; Han, Y. J.; Kang, B.; Chung, Y. D.; Yoon, Y. S.; Chu, S. Y.; Hwang, Y. J.; Jo, H. C.; Jang, J. Y.; Ko, T. K.
DOI
10.1016/j.physc.2011.05.208
발행일
2011-11
유형
Article; Proceedings Paper
저널명
Physica C: Superconductivity and its Applications
권
471
호
21-22
페이지
1424 ~ 1427