상세 보기
대심도 지하역사의 제연/배연 시스템 고찰
- 장용준;
- 김학범;
- 이창현;
- 정우성
초록
In the studying The comparative analysis was performed using numerical simulation for various smoke exhaust and control system against fire in the deeply underground subway station. When the fire occurred in the platform of deeply underground subway station, the evacuation way to exit is long and by way of the concourse. Therefore, the toxic gas inflows should be prevented and delayed to concourse from fire to save passengers' life. In the paper The numerical analyses for various operating in connection with smoke exhaust/control systems of concourse and platform were showed for preventing smoke-inflow into the evacuation way from the fire in the platform of deeply underground subway station.
- 제목
- 대심도 지하역사의 제연/배연 시스템 고찰
- 저자
- 장용준; 김학범; 이창현; 정우성
- 발행일
- 2009-05-20
- 학회명
- 2009 대한기계학회 추계학술대회