상세 보기
초록
Public interest on heating and cooling of cabin is increasing. Especially, abnormal weather condition makes it hard for the railroad operators to obtain the safety and comfort of passengers. Sudden failure in electric power supply may threaten the safety of rail car, as well as the lowered thermal comfort for passengers. For this reason, the change in cabin temperature upon power supply failure was requested to study by a railroad operator. In this study, the change in cabin temperature upon the power supply failure was extensively studied by using a real-scale climatic chamber. The chamber temperature was controlled to 20 ℃ with the cabin heaters operated. After reaching a stable condition in the cabin, the power was off. The cabin temperature was lowered by 16 K in an hour. After 7 h, the temperature decreased by 30 K in 7 hours. The need of good thermal insulation performance could be found out through this study.
- 제목
- 객차의 전원 차단시 객실 온도 변화 연구
- 제목 (타언어)
- Study on Change in Cabin Temperature upon Power Supply Failure
- 저자
- 조영민; 이충희; 박덕신; 권순박; 정우성; 조용성; 김희만
- 발행일
- 2014-05-22
- 학회명
- 2014 한국철도학회 춘계학술발표대회
- 개최지
- 창원컨벤션센터
- 개최국가
- 대한민국
- 학회 개최일
- 2014-05-22 ~ 2014-05-24
- 언어
- KOR